{"uid":"cap_x_4n01UrwZS4BAF6DMKcC","slug":"hodgkin-huxley-membrane-simulation-claim-verifier-f76a08fd","name":"Hodgkin-Huxley Membrane Simulation & Claim Verifier","description":"Reconstruct the complete Hodgkin Huxley voltage dependent sodium potassium gating membrane capacitance charge energy artifact and compare an explicit claim.","url":"https://detect.halowerk.com/v1/F-TD2000-GEO-INDUSTRY-B019/hodgkin-huxley-voltage-gated-membrane-charge-ionic-work-transcript?utm_source=zero.xyz","method":"POST","headers":{},"bodySchema":{"type":"object","properties":{"artifact":{"type":"object","required":["hodgkinHuxley"],"properties":{"hodgkinHuxley":{"type":"object","required":["data","claim"],"properties":{"data":{"type":"object","required":["initial_state","dt_ms","stimulus_segments","sample_steps"],"properties":{"dt_ms":{"type":"number","maximum":0.0001,"minimum":0.000001},"sample_steps":{"type":"array","items":{"type":"integer","maximum":4096,"minimum":0},"maxItems":4,"minItems":1},"initial_state":{"type":"array","items":{"type":"number","maximum":50,"minimum":-100},"maxItems":4,"minItems":4},"stimulus_segments":{"type":"array","items":{"type":"object","required":["steps","current_density"],"properties":{"steps":{"type":"integer","maximum":4096,"minimum":1},"current_density":{"type":"number","maximum":20,"minimum":-20}},"additionalProperties":false},"maxItems":4,"minItems":1}},"additionalProperties":false},"claim":{}},"additionalProperties":false}},"additionalProperties":false}}},"responseSchema":null,"example":null,"exampleRequest":null,"tags":["x402"],"displayCostAmount":"0.003","displayCostAsset":"USDC","priceDynamic":false,"priceHint":null,"priceStatus":"priced","priceSource":"probe","requiresHandshake":false,"reviewCount":0,"rating":{"score":"0.00","successRate":"0.00","reviews":0,"stars":null,"state":"unrated"},"availabilityStatus":"unknown","priceObserved":null,"sessionDeposit":null,"pricing":{"kind":"static","summary":"$0.003/call","primary":{"kind":"static","protocol":"x402","network":"base","amountUsd":"0.003","per":"call","confidence":"exact"},"accepted":[{"kind":"static","protocol":"x402","network":"base","amountUsd":"0.003","per":"call","confidence":"exact"}]},"paymentMethods":[{"uid":"pm_LBP8jBWlSO7Rhd5xnmr8v","protocol":"x402","methodType":"crypto","chain":"base","mode":"charge","costAmount":"0.003","costPer":"request","priority":0,"asset":"0x833589fCD6eDb6E08f4c7C32D4f71b54bdA02913","unit":"request","depositMicros":null,"planRef":null}],"brandName":null,"brandSlug":null,"brandBaseUrl":null,"brandDocsUrl":null,"whatItDoes":"Reconstructs the complete Hodgkin-Huxley voltage-gated sodium/potassium membrane simulation (voltage, gating variables, capacitance, ionic currents, charge, energy) and verifies an explicit claim against the computed trajectory.","exampleAgentPrompt":"Run a Hodgkin-Huxley membrane simulation starting from initial state [-65, 0.05, 0.6, 0.32], with a time step of 0.00005 ms, one stimulus segment of 500 steps at 10 µA/cm², sampling at steps [0, 100, 300, 500], and verify my claim that the peak membrane voltage exceeds 40 mV.","exampleUseCases":[{"title":"Action potential peak voltage verification","prompt":"I have a Hodgkin-Huxley simulation with initial state [-65, 0.05, 0.6, 0.32], dt of 0.00005 ms, a stimulus of 300 steps at 8 µA/cm², and sample points at steps [0, 150, 300]. Verify my claim that an action potential fires and the voltage at step 150 exceeds 20 mV."},{"title":"Ionic energy expenditure claim check","prompt":"For a Hodgkin-Huxley run starting at [-70, 0.04, 0.65, 0.30], time step 0.00002 ms, with two stimulus segments — first 200 steps at 5 µA/cm² then 100 steps at 0 µA/cm² — sampled at [0, 100, 200, 300], check whether the total ionic energy expenditure is less than 50 pJ/cm²."},{"title":"Resting state stability assertion","prompt":"Simulate a Hodgkin-Huxley membrane at initial state [-65, 0.053, 0.596, 0.318], dt 0.00005 ms, with a single 100-step zero-current segment, sampled at steps [0, 50, 100], and verify my claim that the membrane voltage stays within 1 mV of its initial value throughout."}],"resultDescription":"The endpoint returns the reconstructed Hodgkin-Huxley simulation output at the requested sample steps — including membrane voltage, gating variables (m, h, n), ionic currents, membrane charge, and cumulative energy — along with a boolean or structured verdict indicating whether the submitted claim is supported by the computed trajectory.","failureModes":["Invalid initial_state array (must be exactly 4 numbers within [-100, 50])","dt_ms outside valid range [0.000001, 0.0001] causes rejection","stimulus_segments exceed maximum of 4 or contain current_density outside [-20, 20]","sample_steps reference indices beyond the total simulation length","Malformed or absent claim object returns a schema validation error","Numerical instability for extreme stimulus values may produce divergent trajectories"],"whenToPreferThis":"Use this endpoint when you need to both reproduce a Hodgkin-Huxley biophysical membrane simulation from scratch and simultaneously verify a specific quantitative claim about the result — such as peak voltage, gating kinetics, ionic charge, or energy — in a single call. It is ideal for auditing or fact-checking simulation artifacts in neuroscience pipelines, automated scientific claim verification, or adversarial testing of neural membrane models.","instructions":null,"reviewSummary":null,"reviewSummaryHighlights":null,"reviewSummaryConcerns":null,"reviewSummaryGeneratedAt":null,"activationCount":0,"lastUsedAt":null,"lastSuccessfullyRanAt":null,"lastHealthCheckAt":"2026-11-17T00:35:14.519Z","isFirstParty":false,"canonicalSlug":"hodgkin-huxley-membrane-simulation-claim-verifier-f76a08fd"}