{"uid":"cap_kNZ1eZxQG3LCB4FL2vFRB","slug":"ashrae-moist-air-psychrometric-calculator-humidity-enthalpy-dew-point-efbf65a6","name":"ASHRAE Moist-Air Psychrometric Calculator (Humidity, Enthalpy, Dew Point)","description":"ASHRAE liquid-water saturation pressure polynomial for dry bulb 0..80C, ideal moist-air humidity ratio, enthalpy and specific volume; saturation-pressure inverse dew point only >=0C, lower dew point returns unknown. No ice/extrapolation, comfort or health conclusion.","url":"https://detect.halowerk.com/v1/F-TD2000-ENGINEERING-B002/ashrae-water-domain-moist-air-humidity-enthalpy-dewpoint?utm_source=zero.xyz","method":"POST","headers":{},"bodySchema":{"type":"object","properties":{"artifact":{"type":"object","required":["psychrometric"],"properties":{"psychrometric":{"type":"object","required":["data","claim"],"properties":{"data":{"type":"object","required":["temperature_C","pressure_Pa","relative_humidity"],"properties":{"pressure_Pa":{"type":"number","maximum":200000,"minimum":30000},"temperature_C":{"type":"number","maximum":80,"minimum":0},"relative_humidity":{"type":"number","maximum":1,"minimum":0.001}},"additionalProperties":false},"claim":{}},"additionalProperties":false}},"description":"UTF8 JSON artifact at most16000 bytes, computed result20000 bytes; unknown for derived out-of-domain, singular or ill-conditioned systems. Numeric result rounded six decimals. ASHRAE liquid-water saturation pressure polynomial for dry bulb 0..80C, ideal moist-air humidity ratio, enthalpy and specific volume; saturation-pressure inverse dew point only >=0C, lower dew point returns unknown. No ice/extrapolation, comfort or health conclusion.","additionalProperties":false}}},"responseSchema":null,"example":null,"exampleRequest":null,"tags":["x402"],"displayCostAmount":"0.003","displayCostAsset":"USDC","priceDynamic":false,"priceHint":null,"priceStatus":"priced","priceSource":"probe","requiresHandshake":false,"reviewCount":0,"rating":{"score":"0.00","successRate":"0.00","reviews":0,"stars":null,"state":"unrated"},"availabilityStatus":"unknown","priceObserved":null,"sessionDeposit":null,"pricing":{"kind":"static","summary":"$0.003/call","primary":{"kind":"static","protocol":"x402","network":"base","amountUsd":"0.003","per":"call","confidence":"exact"},"accepted":[{"kind":"static","protocol":"x402","network":"base","amountUsd":"0.003","per":"call","confidence":"exact"}]},"paymentMethods":[{"uid":"pm_-saLnQgjuOGgoo5k45_5f","protocol":"x402","methodType":"crypto","chain":"base","mode":"charge","costAmount":"0.003","costPer":"request","priority":0,"asset":"0x833589fCD6eDb6E08f4c7C32D4f71b54bdA02913","unit":"request","depositMicros":null,"planRef":null}],"brandName":null,"brandSlug":null,"brandBaseUrl":null,"brandDocsUrl":null,"whatItDoes":"Computes ASHRAE-standard moist-air psychrometric properties — humidity ratio, enthalpy, specific volume, and dew point — from dry-bulb temperature, atmospheric pressure, and relative humidity for the 0–80°C range.","exampleAgentPrompt":"Calculate the ASHRAE psychrometric properties — humidity ratio, enthalpy, specific volume, and dew point — for moist air at 25°C, 101325 Pa atmospheric pressure, and 60% relative humidity.","exampleUseCases":[{"title":"HVAC cooling load enthalpy calculation","prompt":"I need to know the enthalpy and humidity ratio of outdoor air entering our air handling unit — the conditions are 35°C dry-bulb, 101325 Pa, and 70% relative humidity."},{"title":"Dew point check for condensation risk","prompt":"What's the dew point of air inside a warehouse where the temperature is 18°C, pressure is 98000 Pa, and relative humidity is 85%? I need to know if condensation will form on surfaces."},{"title":"Specific volume for duct sizing","prompt":"Can you compute the specific volume of moist air at 20°C, 101325 Pa, and 50% relative humidity so I can size the supply ductwork properly?"}],"resultDescription":"Returns computed psychrometric properties including: saturation pressure (Pa) via ASHRAE liquid-water polynomial, humidity ratio (kg water / kg dry air), moist-air enthalpy (J/kg), and specific volume (m³/kg). Dew point is returned only when it falls at or above 0°C; below-freezing dew points return 'unknown'. All numeric values are rounded to six decimal places. No comfort or health conclusions are included.","failureModes":["Temperature outside 0–80°C range returns unknown or error — no ice or extrapolation supported","Dew point below 0°C returns 'unknown' — no ice-phase saturation pressure inversion","Relative humidity of 0 (or below 0.001) is rejected as out-of-domain","Pressure outside 30000–200000 Pa range is rejected","Singular or ill-conditioned inputs return 'unknown' rather than a numeric result","Payload exceeding 16000 bytes is rejected"],"whenToPreferThis":"Use this endpoint when you need ASHRAE-standard psychrometric computations for moist air strictly within the liquid-water domain (0–80°C dry bulb). Prefer this over generic formula implementations when you need verified polynomial accuracy for humidity ratio, enthalpy, specific volume, and dew point in HVAC, building energy modeling, or industrial process engineering contexts. Do not use if you need sub-freezing (ice-phase) psychrometrics, comfort indices (PMV, WBGT), or health-based conclusions.","instructions":null,"reviewSummary":null,"reviewSummaryHighlights":null,"reviewSummaryConcerns":null,"reviewSummaryGeneratedAt":null,"activationCount":0,"lastUsedAt":null,"lastSuccessfullyRanAt":null,"lastHealthCheckAt":"2026-11-23T18:45:27.710Z","isFirstParty":false,"canonicalSlug":"ashrae-moist-air-psychrometric-calculator-humidity-enthalpy-dew-point-efbf65a6"}