{"uid":"cap_iksxn7JYe0vNpdhoQR--W","slug":"humanoid-fmea-query-decision-data-studio-d129b352","name":"Humanoid FMEA Query — Decision Data Studio","description":"Local-first data and agent workflow tools from Decision Data Studio, plus verified EU tender shortlists and machine-callable utilities.","url":"https://api.ikoles.dev/v1/humanoid-fmea-query","method":"POST","headers":{},"bodySchema":{"type":"object","properties":{"layer":{"enum":["evidence","design"],"type":"string"},"limit":{"type":"integer","default":10,"maximum":20,"minimum":1},"query":{"type":"string","maxLength":200,"minLength":1},"minRpn":{"type":"number","maximum":1000,"minimum":0},"priority":{"enum":["Critical","High","Medium","Low"],"type":"string"},"evidenceType":{"type":"string","maxLength":100,"minLength":1}}},"responseSchema":{"type":"json","example":{"caveat":"Preliminary research and design-review data; not certification, field reliability evidence, or professional safety approval.","filters":{"limit":5,"query":"battery fire","minRpn":30,"priority":"High"},"license":"CC BY 4.0","records":[{"id":"PWR-01","rpn":40,"tags":["battery","fire"],"cause":"Internal short, mechanical damage, incompatible charger, overtemperature, or manufacturing defect","layer":"design","hazard":"Burns, toxic exposure, fire, and property damage","function":"store and deliver energy","priority":"High","severity":5,"sourceUrl":"https://example.com/source","subsystem":"battery","occurrence":2,"failureMode":"Battery cell enters thermal runaway","localEffect":"Rapid heating, venting, smoke, or fire in pack","sourceTitle":null,"evidenceNote":"Public source","evidenceType":"direct","systemEffect":"Loss of power and possible propagation to adjacent cells and electronics","robotOrDomain":null,"evidenceLocator":"Electrical warnings","evidenceStrength":"direct","verificationTest":"Inject representative sensor faults and a controlled thermal excursion","existingDetection":"Cell voltage and temperature monitoring","detectionDifficulty":4,"recommendedControls":"Use certified matched pack and charger; cell-level monitoring; thermal isolation","singlePointFailureCandidate":true}],"generatedAt":"2026-07-24T04:00:00.000Z","totalRecords":96,"datasetVersion":"1.0.0","matchedRecords":7,"returnedRecords":1}},"example":null,"exampleRequest":null,"tags":["x402"],"displayCostAmount":"0.05","displayCostAsset":"USDC","priceDynamic":false,"priceHint":null,"priceStatus":"priced","priceSource":"probe","requiresHandshake":false,"reviewCount":0,"rating":{"score":"0.00","successRate":"0.00","reviews":0,"stars":null,"state":"unrated"},"availabilityStatus":"unknown","priceObserved":null,"sessionDeposit":null,"pricing":{"kind":"static","summary":"$0.05/call","primary":{"kind":"static","protocol":"x402","network":"base","amountUsd":"0.05","per":"call","confidence":"exact"},"accepted":[{"kind":"static","protocol":"x402","network":"base","amountUsd":"0.05","per":"call","confidence":"exact"}]},"paymentMethods":[{"uid":"pm_aXpAzdme_yDSfOSzftdEi","protocol":"x402","methodType":"crypto","chain":"base","mode":"charge","costAmount":"0.05","costPer":"request","priority":0,"asset":"0x833589fCD6eDb6E08f4c7C32D4f71b54bdA02913","unit":"request","depositMicros":null,"planRef":null}],"brandName":null,"brandSlug":null,"brandBaseUrl":null,"brandDocsUrl":null,"whatItDoes":"Queries a curated FMEA (Failure Mode and Effects Analysis) dataset for humanoid robots, returning ranked failure modes, risk priority numbers, and recommended controls filtered by subsystem, priority, or evidence type.","exampleAgentPrompt":"Search the humanoid robot FMEA database for High-priority design-layer failure modes related to battery fire with an RPN of at least 30, and return up to 5 records.","exampleUseCases":[{"title":"Safety audit for robot power subsystem","prompt":"Pull up to 10 design-layer FMEA records about battery or power failures in humanoid robots where the RPN is at least 50 and priority is Critical — I need the hazard descriptions and recommended controls for a safety review."},{"title":"Evidence review for actuator failures","prompt":"Query the humanoid FMEA database for evidence-layer records about actuator or motor failure modes, limit to 8 results, and show me the evidence strength and source URLs for each one."},{"title":"Identifying single-point failures before deployment","prompt":"Find all High or Critical priority failure modes in the humanoid robot FMEA design layer related to sensing or perception, with a minimum RPN of 40 and up to 15 results — I want to flag any single-point failure candidates before we ship."}],"resultDescription":"Returns a JSON object containing matched FMEA records for humanoid robots, each with: failure mode description, subsystem, function, local and system effects, hazard, severity/occurrence/detection scores, computed RPN, priority level, recommended controls, existing detection methods, verification tests, evidence type and strength, source URL and title, and a single-point failure candidate flag. Also includes metadata: total matched records, returned count, dataset version, generation timestamp, active filters, and a CC BY 4.0 license notice with a disclaimer that results are preliminary research data, not professional safety certification.","failureModes":["Query string too long (exceeds 200 characters) — request rejected","minRpn out of range (below 0 or above 1000) — validation error","limit out of range (below 1 or above 20) — clamped or rejected","Invalid enum value for layer or priority — bad request error","No records match the specified filters — empty records array returned","Service unavailable or payment not processed — 402 or 5xx error"],"whenToPreferThis":"Choose this endpoint when you need structured, curated FMEA data specifically for humanoid robots — covering both design-review and evidence-backed failure modes — with filterable risk priority numbers, subsystem tags, and recommended controls. Prefer it over generic safety databases when you need machine-callable, agent-friendly FMEA retrieval with per-record source attribution and hazard metadata. It is not a substitute for certified field reliability data or professional safety approvals.","instructions":null,"reviewSummary":null,"reviewSummaryHighlights":null,"reviewSummaryConcerns":null,"reviewSummaryGeneratedAt":null,"activationCount":0,"lastUsedAt":null,"lastSuccessfullyRanAt":null,"lastHealthCheckAt":"2026-09-14T12:47:25.005Z","isFirstParty":false}