{"uid":"cap_Yq7cm-LWWQsH3CM_6y6WD","slug":"brushed-dc-motor-exact-electromechanical-state-response-b2bfc7c1","name":"Brushed DC Motor Exact Electromechanical State Response","description":"Exact continuous two-state armature current/rotor speed response to constant voltage and load torque using resistance, inductance, inertia, viscous friction, distinct torque/back-emf constants. Analytic real/complex/repeated eigenvalue matrix exponential; supplied initial condition.","url":"https://detect.halowerk.com/v1/F-TD2000-ENGINEERING-B002/brushed-dc-motor-constant-input-exact-electromechanical-state?utm_source=zero.xyz","method":"POST","headers":{},"bodySchema":{"type":"object","properties":{"artifact":{"type":"object","required":["motor"],"properties":{"motor":{"type":"object","required":["data","claim"],"properties":{"data":{"type":"object","required":["R","L","J","b","Ke","Kt","voltage","load_torque","initial_current","initial_speed","times"],"properties":{"J":{"type":"number","maximum":1000,"minimum":0.0001},"L":{"type":"number","maximum":1000,"minimum":0.0001},"R":{"type":"number","maximum":10000,"minimum":0.001},"b":{"type":"number","maximum":1000,"minimum":0},"Ke":{"type":"number","maximum":1000,"minimum":0.0001},"Kt":{"type":"number","maximum":1000,"minimum":0.0001},"times":{"type":"array","items":{"type":"number","maximum":100,"minimum":0},"maxItems":100,"minItems":1},"voltage":{"type":"number","maximum":1000,"minimum":-1000},"load_torque":{"type":"number","maximum":1000,"minimum":-1000},"initial_speed":{"type":"number","maximum":10000,"minimum":-10000},"initial_current":{"type":"number","maximum":10000,"minimum":-10000}},"additionalProperties":false},"claim":{}},"additionalProperties":false}},"description":"UTF8 JSON artifact at most16000 bytes, computed result20000 bytes; unknown for derived out-of-domain, singular or ill-conditioned systems. Numeric result rounded six decimals. Exact continuous two-state armature current/rotor speed response to constant voltage and load torque using resistance, inductance, inertia, viscous friction, distinct torque/back-emf constants. Analytic real/complex/repeated eigenvalue matrix exponential; supplied initial condition.","additionalProperties":false}}},"responseSchema":null,"example":null,"exampleRequest":null,"tags":["x402"],"displayCostAmount":"0.003","displayCostAsset":"USDC","priceDynamic":false,"priceHint":null,"priceStatus":"priced","priceSource":"probe","requiresHandshake":false,"reviewCount":0,"rating":{"score":"0.00","successRate":"0.00","reviews":0,"stars":null,"state":"unrated"},"availabilityStatus":"unknown","priceObserved":null,"sessionDeposit":null,"pricing":{"kind":"static","summary":"$0.003/call","primary":{"kind":"static","protocol":"x402","network":"base","amountUsd":"0.003","per":"call","confidence":"exact"},"accepted":[{"kind":"static","protocol":"x402","network":"base","amountUsd":"0.003","per":"call","confidence":"exact"}]},"paymentMethods":[{"uid":"pm_tKK86kwnYA_PONQSA-y_t","protocol":"x402","methodType":"crypto","chain":"base","mode":"charge","costAmount":"0.003","costPer":"request","priority":0,"asset":"0x833589fCD6eDb6E08f4c7C32D4f71b54bdA02913","unit":"request","depositMicros":null,"planRef":null}],"brandName":null,"brandSlug":null,"brandBaseUrl":null,"brandDocsUrl":null,"whatItDoes":"Computes the exact continuous-time armature current and rotor speed transient response of a brushed DC motor to constant voltage and load torque inputs using analytic matrix-exponential methods.","exampleAgentPrompt":"Compute the exact armature current and rotor speed response of a brushed DC motor with R=2 ohm, L=0.005 H, J=0.01 kg·m², b=0.1 N·m·s, Ke=0.01 V·s/rad, Kt=0.01 N·m/A, driven at 24 V with a 0.5 N·m load torque, starting from zero current and zero speed, evaluated at t=0, 0.05, 0.1, 0.5, 1.0 seconds.","exampleUseCases":[{"title":"Step voltage motor startup simulation","prompt":"I need to simulate how quickly my brushed DC motor reaches steady-state speed when I apply 12 V. The motor has R=1.5 ohm, L=0.003 H, J=0.005 kg·m², b=0.02 N·m·s, Ke=0.008 V·s/rad, Kt=0.008 N·m/A, with no load torque, starting from rest. Can you give me the exact current and speed at t=0, 0.01, 0.05, 0.1, 0.5, 1.0 seconds?"},{"title":"Motor braking transient with initial speed","prompt":"My motor is spinning at 300 rad/s with 5 A initial current and I want to know how the current and speed decay when I apply 0 V and a 0.2 N·m braking torque. Parameters: R=3 ohm, L=0.002 H, J=0.02 kg·m², b=0.05 N·m·s, Ke=0.015 V·s/rad, Kt=0.015 N·m/A. Give me exact values at t=0, 0.1, 0.25, 0.5, 1.0, 2.0 seconds."},{"title":"Control design steady-state verification","prompt":"For a motor controller design check, calculate the exact armature current and rotor speed at t=0.001, 0.005, 0.01, 0.1, 1.0 s for a motor with R=5 ohm, L=0.01 H, J=0.008 kg·m², b=0.03 N·m·s, Ke=0.05 V·s/rad, Kt=0.05 N·m/A, driven at 48 V with a constant 1.0 N·m load, starting from 0 A and 0 rad/s."}],"resultDescription":"Returns the exact continuous-time armature current (A) and rotor speed (rad/s) at each requested time point, computed via analytic matrix-exponential with eigenvalue decomposition (handling real, complex, and repeated eigenvalue cases). Results are rounded to six decimal places. Suitable for validating motor controllers, verifying numerical solvers, and generating ground-truth transient trajectories.","failureModes":["Singular or ill-conditioned system matrices (e.g., near-zero determinant) result in unknown/undefined output","Parameters outside allowed ranges (e.g., R < 0.001, L < 0.0001, J < 0.0001) are rejected with validation errors","Input artifact exceeding 16000 bytes is rejected","More than 100 time points requested triggers a validation error","Time values outside [0, 100] are rejected","Payment failure or insufficient USDC balance returns a 402 error"],"whenToPreferThis":"Use this endpoint when you need analytically exact (not numerically integrated) continuous-time state trajectories for a two-state brushed DC motor model with constant voltage and load torque inputs. It is ideal for generating ground-truth reference solutions, validating numerical ODE solvers, performing control design verification, or when floating-point integration error is unacceptable. It handles all eigenvalue cases (real, complex, repeated) correctly, making it more robust than general-purpose ODE solvers for stiff or near-degenerate systems.","instructions":null,"reviewSummary":null,"reviewSummaryHighlights":null,"reviewSummaryConcerns":null,"reviewSummaryGeneratedAt":null,"activationCount":0,"lastUsedAt":null,"lastSuccessfullyRanAt":null,"lastHealthCheckAt":"2026-11-17T00:37:40.743Z","isFirstParty":false,"canonicalSlug":"brushed-dc-motor-exact-electromechanical-state-response-b2bfc7c1"}