{"uid":"cap_CVyTZaPkIGIKJAtDHA_it","slug":"halowerk-pinch-analysis-heat-cascade-minimum-utilities-calculator-3b7d09fc","name":"Halowerk Pinch Analysis Heat Cascade Minimum Utilities Calculator","description":"Compute mathematical heat-recovery utility targets from supplied stream tables.","url":"https://detect.halowerk.com/v1/F-TD2000-ENGINEERING-B001/shifted-temperature-stream-heat-cascade-minimum-utilities?utm_source=zero.xyz","method":"POST","headers":{},"bodySchema":{"type":"object","properties":{"artifact":{"type":"object","required":["pinch"],"properties":{"pinch":{"type":"object","required":["data","claim"],"properties":{"data":{"type":"object","required":["minimum_approach","streams"],"properties":{"streams":{"type":"array","items":{"type":"object","required":["kind","supply","target","heat_capacity_flow"],"properties":{"kind":{"enum":["hot","cold"]},"supply":{"type":"number","maximum":10000,"minimum":-273},"target":{"type":"number","maximum":10000,"minimum":-273},"heat_capacity_flow":{"type":"number","maximum":100000,"minimum":0.000001}},"additionalProperties":false},"maxItems":48,"minItems":1},"minimum_approach":{"type":"number","maximum":1000,"minimum":0}},"additionalProperties":false},"claim":{}},"additionalProperties":false}},"additionalProperties":false}}},"responseSchema":null,"example":null,"exampleRequest":null,"tags":["x402"],"displayCostAmount":"0.003","displayCostAsset":"USDC","priceDynamic":false,"priceHint":null,"priceStatus":"priced","priceSource":"probe","requiresHandshake":false,"reviewCount":0,"rating":{"score":"0.00","successRate":"0.00","reviews":0,"stars":null,"state":"unrated"},"availabilityStatus":"unknown","priceObserved":null,"sessionDeposit":null,"pricing":{"kind":"static","summary":"$0.003/call","primary":{"kind":"static","protocol":"x402","network":"base","amountUsd":"0.003","per":"call","confidence":"exact"},"accepted":[{"kind":"static","protocol":"x402","network":"base","amountUsd":"0.003","per":"call","confidence":"exact"}]},"paymentMethods":[{"uid":"pm_5lrBZUeG5rlef21G8F38V","protocol":"x402","methodType":"crypto","chain":"base","mode":"charge","costAmount":"0.003","costPer":"request","priority":0,"asset":"0x833589fCD6eDb6E08f4c7C32D4f71b54bdA02913","unit":"request","depositMicros":null,"planRef":null}],"brandName":null,"brandSlug":null,"brandBaseUrl":null,"brandDocsUrl":null,"whatItDoes":"Computes minimum hot and cold utility targets for a set of process streams using shifted temperature heat cascade (pinch analysis) methodology.","exampleAgentPrompt":"Run a pinch analysis heat cascade on these three streams with a minimum approach temperature of 10°C: a hot stream from 150°C to 60°C with CP=2.5 kW/°C, a cold stream from 20°C to 130°C with CP=3.0 kW/°C, and another hot stream from 200°C to 80°C with CP=1.8 kW/°C — give me the minimum hot and cold utility targets.","exampleUseCases":[{"title":"Refinery heat integration energy targeting","prompt":"I have a refinery distillation unit with four process streams — two hot streams and two cold streams — and I want to know the absolute minimum heating and cooling utilities needed. Hot stream 1 goes from 180°C to 40°C with CP=4.0 kW/°C, hot stream 2 from 120°C to 30°C with CP=2.2 kW/°C, cold stream 1 from 25°C to 110°C with CP=3.5 kW/°C, cold stream 2 from 50°C to 160°C with CP=1.9 kW/°C. Use a ΔTmin of 15°C."},{"title":"Pharmaceutical process energy audit","prompt":"Can you compute the heat cascade and minimum utilities for a pharmaceutical batch process? I have one hot stream (200°C to 80°C, CP=1.5 kW/°C) and two cold streams (30°C to 150°C, CP=2.0 kW/°C and 60°C to 170°C, CP=1.2 kW/°C). Set the minimum approach temperature to 20°C."},{"title":"Chemical plant retrofit pinch study","prompt":"We're retrofitting a chemical plant and need to establish energy targets before redesigning our heat exchanger network. Run a shifted temperature heat cascade with ΔTmin=10°C on these streams: hot stream A (250°C→100°C, CP=5.0 kW/°C), hot stream B (140°C→50°C, CP=2.8 kW/°C), cold stream C (20°C→200°C, CP=4.2 kW/°C), cold stream D (45°C→120°C, CP=3.1 kW/°C). What are the minimum hot and cold utility requirements?"}],"resultDescription":"Returns the minimum hot utility target (QHmin) and minimum cold utility target (QCmin) for the supplied process streams, along with the heat cascade interval breakdown and pinch temperature(s) derived from the shifted temperature composite curves.","failureModes":["Invalid stream temperatures outside the range -273 to 10000°C return a validation error","Heat capacity flow rate of zero or below the minimum threshold (0.000001) causes rejection","Supplying more than 48 streams exceeds the maxItems limit and returns a schema error","Supply temperature equal to target temperature may cause degenerate or zero-duty streams","Negative minimum_approach temperature (below 0) is rejected by schema validation","Missing required fields (kind, supply, target, heat_capacity_flow) cause 400 errors","Thermodynamically infeasible cascade configurations may return null or zero utility values"],"whenToPreferThis":"Use this endpoint when you need rigorous mathematical pinch analysis (heat cascade method) to establish theoretical minimum utility targets for a set of process streams before designing or retrofitting a heat exchanger network. It is ideal for chemical, refinery, pharmaceutical, or any industrial process engineering context where you have tabulated stream data (supply temperature, target temperature, CP values) and need to apply Linnhoff's pinch methodology computationally. Prefer this over manual spreadsheet calculations or general-purpose math solvers when you need a structured, validated result with pinch point identification.","instructions":null,"reviewSummary":null,"reviewSummaryHighlights":null,"reviewSummaryConcerns":null,"reviewSummaryGeneratedAt":null,"activationCount":0,"lastUsedAt":null,"lastSuccessfullyRanAt":null,"lastHealthCheckAt":"2026-11-17T00:38:09.121Z","isFirstParty":false,"canonicalSlug":"halowerk-pinch-analysis-heat-cascade-minimum-utilities-calculator-3b7d09fc"}