{"uid":"cap_7WgqYrDNoh_n435c1VoOS","slug":"brainiac-breaker-rating-check-api-aca59971","name":"BRAINIAC Breaker Rating Check API","description":"Pay-per-call APIs for AI agents: OFAC sanctions screening, compliance checks, token security, and Base chain data via x402. No account. Fixed USDC price. MCP-ready.","url":"https://www.brainiac.software/api/v1/electrical-engineering/breaker-rating-check?utm_source=zero.xyz","method":"POST","headers":{},"bodySchema":{"type":"object","properties":{"csv":{"type":"string","maxLength":200000},"asOf":{"type":"string","maxLength":40},"file":{"type":"object","required":["mediaType","fileBase64"],"properties":{"filename":{"type":"string","maxLength":180,"minLength":1},"mediaType":{"enum":["text/plain","text/csv","application/json"],"type":"string"},"fileBase64":{"type":"string","maxLength":12000000,"minLength":1}},"additionalProperties":false},"json":{"type":"string","maxLength":200000},"text":{"type":"string","maxLength":200000},"loads":{"type":"array","items":{"type":"object","properties":{"id":{"type":"string","maxLength":80},"kw":{"type":"number","maximum":1000000000,"minimum":0},"kva":{"type":"number","maximum":1000000000,"minimum":0},"name":{"type":"string","maxLength":200},"notes":{"type":"string","maxLength":300},"phase":{"enum":["1","3","A","B","C","AB","BC","CA","ABC"],"type":"string"},"lengthM":{"type":"number","maximum":1000000,"minimum":0},"currentA":{"type":"number","maximum":1000000000,"minimum":0},"quantity":{"type":"number","maximum":1000000,"minimum":0},"voltageV":{"type":"number","maximum":1000000,"minimum":0},"continuous":{"type":"boolean"},"powerFactor":{"type":"number","maximum":1,"minimum":0}},"additionalProperties":false},"maxItems":500},"rules":{"type":"array","items":{"type":"object","properties":{"id":{"type":"string","maxLength":80},"code":{"type":"string","maxLength":80},"unit":{"type":"string","maxLength":40},"source":{"type":"string","maxLength":200},"subject":{"type":"string","maxLength":120},"threshold":{"type":"number","maximum":1000000000,"minimum":-1000000000},"description":{"type":"string","maxLength":400}},"additionalProperties":false},"maxItems":200},"cables":{"type":"array","items":{"type":"object","properties":{"id":{"type":"string","maxLength":80},"loadId":{"type":"string","maxLength":80},"lengthM":{"type":"number","maximum":1000000,"minimum":0},"material":{"type":"string","maxLength":40},"ampacityA":{"type":"number","maximum":1000000,"minimum":0},"sizeLabel":{"type":"string","maxLength":80},"conductors":{"type":"integer","maximum":100,"minimum":1},"designation":{"type":"string","maxLength":120},"reactanceOhmPerKm":{"type":"number","maximum":1000000,"minimum":0},"resistanceOhmPerKm":{"type":"number","maximum":1000000,"minimum":0}},"additionalProperties":false},"maxItems":500},"system":{"type":"object","properties":{"phases":{"type":"integer","maximum":3,"minimum":1},"voltageV":{"type":"number","maximum":1000000,"minimum":0},"frequencyHz":{"type":"number","maximum":1000,"minimum":0},"powerFactor":{"type":"number","maximum":1,"minimum":0.01},"continuousFactor":{"type":"number","maximum":2,"minimum":0}},"additionalProperties":false},"breakers":{"type":"array","items":{"type":"object","properties":{"id":{"type":"string","maxLength":80},"type":{"type":"string","maxLength":80},"poles":{"type":"integer","maximum":4,"minimum":1},"loadId":{"type":"string","maxLength":80},"ratingA":{"type":"number","maximum":1000000,"minimum":0},"continuousFactor":{"type":"number","maximum":2,"minimum":0}},"additionalProperties":false},"maxItems":500},"chargers":{"type":"array","items":{"type":"object","properties":{"id":{"type":"string","maxLength":80},"kw":{"type":"number","maximum":1000000,"minimum":0},"name":{"type":"string","maxLength":160},"phases":{"type":"integer","maximum":3,"minimum":1},"currentA":{"type":"number","maximum":1000000,"minimum":0},"quantity":{"type":"number","maximum":1000000,"minimum":0},"voltageV":{"type":"number","maximum":1000000,"minimum":0},"continuous":{"type":"boolean"},"existingLoadA":{"type":"number","maximum":1000000,"minimum":0},"panelCapacityA":{"type":"number","maximum":1000000,"minimum":0},"continuousFactor":{"type":"number","maximum":2,"minimum":0}},"additionalProperties":false},"maxItems":200},"generators":{"type":"array","items":{"type":"object","properties":{"id":{"type":"string","maxLength":80},"name":{"type":"string","maxLength":160},"loadKw":{"type":"number","maximum":1000000000,"minimum":0},"loadKva":{"type":"number","maximum":1000000000,"minimum":0},"ratedKva":{"type":"number","maximum":1000000000,"minimum":0},"powerFactor":{"type":"number","maximum":1,"minimum":0.01},"reserveFactor":{"type":"number","maximum":10,"minimum":0},"altitudeDerate":{"type":"number","maximum":1,"minimum":0},"diversityFactor":{"type":"number","maximum":10,"minimum":0},"temperatureDerate":{"type":"number","maximum":1,"minimum":0}},"additionalProperties":false},"maxItems":100},"transformers":{"type":"array","items":{"type":"object","properties":{"id":{"type":"string","maxLength":80},"name":{"type":"string","maxLength":160},"loadKva":{"type":"number","maximum":1000000000,"minimum":0},"primaryV":{"type":"number","maximum":1000000,"minimum":0},"ratedKva":{"type":"number","maximum":1000000000,"minimum":0},"secondaryV":{"type":"number","maximum":1000000,"minimum":0},"impedancePct":{"type":"number","maximum":100,"minimum":0}},"additionalProperties":false},"maxItems":100},"powerFactorCases":{"type":"array","items":{"type":"object","properties":{"id":{"type":"string","maxLength":80},"kw":{"type":"number","maximum":1000000000,"minimum":0},"voltageV":{"type":"number","maximum":1000000,"minimum":0},"frequencyHz":{"type":"number","maximum":1000,"minimum":0},"powerFactor":{"type":"number","maximum":1,"minimum":0.01},"targetPowerFactor":{"type":"number","maximum":1,"minimum":0.01}},"additionalProperties":false},"maxItems":100}}},"responseSchema":{"type":"json","example":{"items":[{"type":"MCCB","poles":3,"loadId":"L1","ratingA":100,"adequate":true,"breakerId":"BK1","loadCurrentA":76.414,"polesSupplied":true,"designCurrentA":95.5175,"ratingSupplied":true,"adequateSupplied":true,"continuousFactor":1.25,"standardsInvented":false,"loadCurrentSupplied":true,"codeComplianceClaimed":false,"designCurrentSupplied":true,"continuousFactorSupplied":true}],"status":"checked","findings":[],"checkedAt":"2026-11-04T21:00:00.000Z","limitations":["Loads, cables, breakers, transformers, power-factor cases, generators, chargers, and optional rule thresholds are copied only from labeled fields supplied by the caller.","No paid engineering data provider is used and no API key is required.","Deterministic formulas use caller-supplied voltages, currents, impedances, ratings, and factors. Missing values are not invented.","Electrical code or safety compliance is not claimed. Caller-supplied rule thresholds are compared when present; standards tables are not invented.","Cable ampacity tables, breaker continuous factors, and derating rules are applied only when the caller supplies those values."],"breakerCount":1,"apiKeyRequired":false,"paidProviderUsed":false,"standardsInvented":false,"codeComplianceClaimed":false}},"example":null,"exampleRequest":null,"tags":["x402"],"displayCostAmount":"0.03","displayCostAsset":"USDC","priceDynamic":false,"priceHint":null,"priceStatus":"priced","priceSource":"probe","requiresHandshake":false,"reviewCount":0,"rating":{"score":"0.00","successRate":"0.00","reviews":0,"stars":null,"state":"unrated"},"availabilityStatus":"unknown","priceObserved":null,"sessionDeposit":null,"pricing":{"kind":"static","summary":"$0.03/call","primary":{"kind":"static","protocol":"x402","network":"base","amountUsd":"0.03","per":"call","confidence":"exact"},"accepted":[{"kind":"static","protocol":"x402","network":"base","amountUsd":"0.03","per":"call","confidence":"exact"}]},"paymentMethods":[{"uid":"pm_P4czec-Kv3MeUd0up9wel","protocol":"x402","methodType":"crypto","chain":"base","mode":"charge","costAmount":"0.03","costPer":"request","priority":0,"asset":"0x833589fCD6eDb6E08f4c7C32D4f71b54bdA02913","unit":"request","depositMicros":null,"planRef":null}],"brandName":null,"brandSlug":null,"brandBaseUrl":null,"brandDocsUrl":null,"whatItDoes":"Validates circuit breaker ratings against load current, design current, and optional custom rule thresholds using deterministic electrical engineering formulas","exampleAgentPrompt":"Check if a 100A, 3-pole MCCB breaker (ID: BK1) is correctly rated for load L1 drawing 76.4A at 480V, 3-phase with a 1.25 continuous factor — give me the design current and whether the breaker is adequate.","exampleUseCases":[{"title":"Panel schedule breaker audit","prompt":"I have a panel schedule as a CSV with loads, voltages, and breaker ratings — can you check whether every breaker is adequately sized for its load, accounting for continuous loads at 125%?"},{"title":"Single MCCB validation for motor load","prompt":"I need to verify that my 200A, 3-pole MCCB is sufficient for a continuous 3-phase motor load drawing 140A at 480V with a 0.85 power factor — does the breaker rating hold up?"},{"title":"Custom rule threshold compliance check","prompt":"Run a breaker rating check on these three loads at 208V single-phase: 15kW continuous on a 100A breaker, 8kW non-continuous on a 60A breaker, and 20kW continuous on a 125A breaker — flag any that fail a design current threshold of 1.25× load current."}],"resultDescription":"Returns a JSON object with an array of breaker check items (one per breaker), each including: breaker ID, type, poles, rating in amps, load current, design current, continuous factor, and boolean flags for adequacy, rating supplied, poles supplied, and code compliance claimed. Also includes overall status, findings array, checkedAt timestamp, breaker count, and a limitations array clarifying that no standards tables are invented and compliance is not claimed.","failureModes":["Missing required voltage or current values — missing values are not invented, so calculations may be incomplete","Loads or breakers not supplied in recognized fields — unrecognized structure is not parsed","Exceeding maxItems limits (500 loads, 200 rules) — request will be rejected","Invalid phase enum value — validation error returned","CSV or JSON malformed — parsing failure with error response","Payment not received via x402 — HTTP 402 response before processing"],"whenToPreferThis":"Use this endpoint when you need deterministic, formula-based breaker sizing validation using caller-supplied electrical parameters without relying on proprietary standards databases. It is ideal for automated panel schedule audits, design review workflows, or agent-driven electrical checks where you supply voltages, currents, ampacity, and optional custom rule thresholds. Prefer this over manual calculation when processing many loads in one call (up to 500 loads, 200 rules). Note: it does not claim NEC or code compliance and does not invent missing values — suitable for preliminary design validation, not final engineering sign-off.","instructions":null,"reviewSummary":null,"reviewSummaryHighlights":null,"reviewSummaryConcerns":null,"reviewSummaryGeneratedAt":null,"activationCount":0,"lastUsedAt":null,"lastSuccessfullyRanAt":null,"lastHealthCheckAt":"2026-11-12T18:39:44.251Z","isFirstParty":false,"canonicalSlug":"brainiac-breaker-rating-check-api-aca59971"}