{"uid":"cap_4GALNBfTAJqEUMOlKlEzj","slug":"brainiac-electrical-load-schedule-calculator-4817d593","name":"BRAINIAC Electrical Load Schedule Calculator","description":"Pay-per-call APIs for AI agents: OFAC sanctions screening, compliance checks, token security, and Base chain data via x402. No account. Fixed USDC price. MCP-ready.","url":"https://www.brainiac.software/api/v1/electrical-engineering/load-schedule-calculate?utm_source=zero.xyz","method":"POST","headers":{},"bodySchema":{"type":"object","properties":{"csv":{"type":"string","maxLength":200000},"asOf":{"type":"string","maxLength":40},"file":{"type":"object","required":["mediaType","fileBase64"],"properties":{"filename":{"type":"string","maxLength":180,"minLength":1},"mediaType":{"enum":["text/plain","text/csv","application/json"],"type":"string"},"fileBase64":{"type":"string","maxLength":12000000,"minLength":1}},"additionalProperties":false},"json":{"type":"string","maxLength":200000},"text":{"type":"string","maxLength":200000},"loads":{"type":"array","items":{"type":"object","properties":{"id":{"type":"string","maxLength":80},"kw":{"type":"number","maximum":1000000000,"minimum":0},"kva":{"type":"number","maximum":1000000000,"minimum":0},"name":{"type":"string","maxLength":200},"notes":{"type":"string","maxLength":300},"phase":{"enum":["1","3","A","B","C","AB","BC","CA","ABC"],"type":"string"},"lengthM":{"type":"number","maximum":1000000,"minimum":0},"currentA":{"type":"number","maximum":1000000000,"minimum":0},"quantity":{"type":"number","maximum":1000000,"minimum":0},"voltageV":{"type":"number","maximum":1000000,"minimum":0},"continuous":{"type":"boolean"},"powerFactor":{"type":"number","maximum":1,"minimum":0}},"additionalProperties":false},"maxItems":500},"rules":{"type":"array","items":{"type":"object","properties":{"id":{"type":"string","maxLength":80},"code":{"type":"string","maxLength":80},"unit":{"type":"string","maxLength":40},"source":{"type":"string","maxLength":200},"subject":{"type":"string","maxLength":120},"threshold":{"type":"number","maximum":1000000000,"minimum":-1000000000},"description":{"type":"string","maxLength":400}},"additionalProperties":false},"maxItems":200},"cables":{"type":"array","items":{"type":"object","properties":{"id":{"type":"string","maxLength":80},"loadId":{"type":"string","maxLength":80},"lengthM":{"type":"number","maximum":1000000,"minimum":0},"material":{"type":"string","maxLength":40},"ampacityA":{"type":"number","maximum":1000000,"minimum":0},"sizeLabel":{"type":"string","maxLength":80},"conductors":{"type":"integer","maximum":100,"minimum":1},"designation":{"type":"string","maxLength":120},"reactanceOhmPerKm":{"type":"number","maximum":1000000,"minimum":0},"resistanceOhmPerKm":{"type":"number","maximum":1000000,"minimum":0}},"additionalProperties":false},"maxItems":500},"system":{"type":"object","properties":{"phases":{"type":"integer","maximum":3,"minimum":1},"voltageV":{"type":"number","maximum":1000000,"minimum":0},"frequencyHz":{"type":"number","maximum":1000,"minimum":0},"powerFactor":{"type":"number","maximum":1,"minimum":0.01},"continuousFactor":{"type":"number","maximum":2,"minimum":0}},"additionalProperties":false},"breakers":{"type":"array","items":{"type":"object","properties":{"id":{"type":"string","maxLength":80},"type":{"type":"string","maxLength":80},"poles":{"type":"integer","maximum":4,"minimum":1},"loadId":{"type":"string","maxLength":80},"ratingA":{"type":"number","maximum":1000000,"minimum":0},"continuousFactor":{"type":"number","maximum":2,"minimum":0}},"additionalProperties":false},"maxItems":500},"chargers":{"type":"array","items":{"type":"object","properties":{"id":{"type":"string","maxLength":80},"kw":{"type":"number","maximum":1000000,"minimum":0},"name":{"type":"string","maxLength":160},"phases":{"type":"integer","maximum":3,"minimum":1},"currentA":{"type":"number","maximum":1000000,"minimum":0},"quantity":{"type":"number","maximum":1000000,"minimum":0},"voltageV":{"type":"number","maximum":1000000,"minimum":0},"continuous":{"type":"boolean"},"existingLoadA":{"type":"number","maximum":1000000,"minimum":0},"panelCapacityA":{"type":"number","maximum":1000000,"minimum":0},"continuousFactor":{"type":"number","maximum":2,"minimum":0}},"additionalProperties":false},"maxItems":200},"generators":{"type":"array","items":{"type":"object","properties":{"id":{"type":"string","maxLength":80},"name":{"type":"string","maxLength":160},"loadKw":{"type":"number","maximum":1000000000,"minimum":0},"loadKva":{"type":"number","maximum":1000000000,"minimum":0},"ratedKva":{"type":"number","maximum":1000000000,"minimum":0},"powerFactor":{"type":"number","maximum":1,"minimum":0.01},"reserveFactor":{"type":"number","maximum":10,"minimum":0},"altitudeDerate":{"type":"number","maximum":1,"minimum":0},"diversityFactor":{"type":"number","maximum":10,"minimum":0},"temperatureDerate":{"type":"number","maximum":1,"minimum":0}},"additionalProperties":false},"maxItems":100},"transformers":{"type":"array","items":{"type":"object","properties":{"id":{"type":"string","maxLength":80},"name":{"type":"string","maxLength":160},"loadKva":{"type":"number","maximum":1000000000,"minimum":0},"primaryV":{"type":"number","maximum":1000000,"minimum":0},"ratedKva":{"type":"number","maximum":1000000000,"minimum":0},"secondaryV":{"type":"number","maximum":1000000,"minimum":0},"impedancePct":{"type":"number","maximum":100,"minimum":0}},"additionalProperties":false},"maxItems":100},"powerFactorCases":{"type":"array","items":{"type":"object","properties":{"id":{"type":"string","maxLength":80},"kw":{"type":"number","maximum":1000000000,"minimum":0},"voltageV":{"type":"number","maximum":1000000,"minimum":0},"frequencyHz":{"type":"number","maximum":1000,"minimum":0},"powerFactor":{"type":"number","maximum":1,"minimum":0.01},"targetPowerFactor":{"type":"number","maximum":1,"minimum":0.01}},"additionalProperties":false},"maxItems":100}}},"responseSchema":{"type":"json","example":{"items":[{"id":"L1","kw":45,"kva":52.9412,"name":"HVAC","notes":"","phase":"ABC","currentA":76.414,"quantity":1,"voltageV":400,"continuous":true,"kwSupplied":true,"threePhase":true,"kvaSupplied":true,"powerFactor":0.85,"currentSupplied":true,"voltageSupplied":true,"standardsInvented":false,"continuousSupplied":true,"powerFactorSupplied":true,"codeComplianceClaimed":false},{"id":"L2","kw":8,"kva":8.4211,"name":"Lighting A","notes":"","phase":"A","currentA":21.0526,"quantity":1,"voltageV":400,"continuous":false,"kwSupplied":true,"threePhase":false,"kvaSupplied":true,"powerFactor":0.95,"currentSupplied":true,"voltageSupplied":true,"standardsInvented":false,"continuousSupplied":false,"powerFactorSupplied":true,"codeComplianceClaimed":false}],"status":"calculated","totalKw":53,"findings":[],"totalKva":61.3623,"checkedAt":"2026-11-04T21:00:00.000Z","loadCount":2,"limitations":["Loads, cables, breakers, transformers, power-factor cases, generators, chargers, and optional rule thresholds are copied only from labeled fields supplied by the caller.","No paid engineering data provider is used and no API key is required.","Deterministic formulas use caller-supplied voltages, currents, impedances, ratings, and factors. Missing values are not invented.","Electrical code or safety compliance is not claimed. Caller-supplied rule thresholds are compared when present; standards tables are not invented.","Cable ampacity tables, breaker continuous factors, and derating rules are applied only when the caller supplies those values."],"apiKeyRequired":false,"totalKwSupplied":true,"paidProviderUsed":false,"totalKvaSupplied":true,"standardsInvented":false,"codeComplianceClaimed":false}},"example":null,"exampleRequest":null,"tags":["x402"],"displayCostAmount":"0.04","displayCostAsset":"USDC","priceDynamic":false,"priceHint":null,"priceStatus":"priced","priceSource":"probe","requiresHandshake":false,"reviewCount":0,"rating":{"score":"0.00","successRate":"0.00","reviews":0,"stars":null,"state":"unrated"},"availabilityStatus":"unknown","priceObserved":null,"sessionDeposit":null,"pricing":{"kind":"static","summary":"$0.04/call","primary":{"kind":"static","protocol":"x402","network":"base","amountUsd":"0.04","per":"call","confidence":"exact"},"accepted":[{"kind":"static","protocol":"x402","network":"base","amountUsd":"0.04","per":"call","confidence":"exact"}]},"paymentMethods":[{"uid":"pm_C9Gik9Z2P102kwvG_uZeI","protocol":"x402","methodType":"crypto","chain":"base","mode":"charge","costAmount":"0.04","costPer":"request","priority":0,"asset":"0x833589fCD6eDb6E08f4c7C32D4f71b54bdA02913","unit":"request","depositMicros":null,"planRef":null}],"brandName":null,"brandSlug":null,"brandBaseUrl":null,"brandDocsUrl":null,"whatItDoes":"Calculates electrical load schedules including total kW/kVA, current, power factor, and optional code-compliance checks for a set of electrical loads, cables, breakers, and transformers.","exampleAgentPrompt":"Can you calculate the load schedule for my facility? I have an HVAC unit at 45 kW, 400V, 3-phase, 0.85 power factor running continuously, and a lighting circuit at 8 kW, 400V, single-phase A, 0.95 power factor — give me the totals including kVA and current for each load.","exampleUseCases":[{"title":"Commercial building electrical load summary","prompt":"I need a load schedule for a small office building — I have 3 loads: 60 kW HVAC at 400V 3-phase 0.85 PF continuous, 10 kW lighting at 230V single-phase 0.95 PF, and a 5 kW server room at 230V single-phase 0.9 PF. Calculate total kW, kVA, and current for each."},{"title":"Industrial panel compliance check","prompt":"Run a load schedule calculation for my industrial panel with these loads: a 200 kW motor at 480V 3-phase 0.8 PF and a 50 kW compressor at 480V 3-phase 0.85 PF, both continuous. Also check that no single load current exceeds 300A using that as a rule threshold."},{"title":"Phase load balancing analysis","prompt":"I have an unbalanced electrical load setup — lighting A phase at 8 kW 230V 0.95 PF, lighting B phase at 6 kW 230V 0.95 PF, and lighting C phase at 10 kW 230V 0.95 PF. Can you calculate the per-load currents and totals so I can see how unbalanced the phases are?"}],"resultDescription":"Returns a JSON object with per-load details (kW, kVA, current, phase, power factor, flags for which values were supplied vs. calculated), aggregate totals (totalKw, totalKva, loadCount), a findings array listing any rule violations or issues, the calculation timestamp, and a limitations list clarifying what the engine did and did not assume or invent.","failureModes":["Missing required voltage or current values result in those fields being omitted rather than estimated","Loads exceeding 500 items are rejected","CSV/JSON text inputs that don't parse into recognizable load fields may produce empty or partial results","Custom rules with missing thresholds are ignored silently","Very large file inputs (>12MB base64) are rejected","No electrical code tables are built in — compliance checks only fire on caller-supplied rule thresholds"],"whenToPreferThis":"Use this endpoint when you need deterministic, formula-based electrical load schedule calculations without signing up for an account or obtaining API keys, and when you want pay-per-call pricing via USDC on Base. Prefer this over manual spreadsheet calculations or full electrical design software when you need fast, structured output with optional rule-threshold compliance checking for a set of up to 500 loads. Not suitable when you need certified engineering sign-off or built-in NEC/IEC code tables — it only checks rules you explicitly supply.","instructions":null,"reviewSummary":null,"reviewSummaryHighlights":null,"reviewSummaryConcerns":null,"reviewSummaryGeneratedAt":null,"activationCount":0,"lastUsedAt":null,"lastSuccessfullyRanAt":null,"lastHealthCheckAt":"2026-11-12T18:39:43.645Z","isFirstParty":false,"canonicalSlug":"brainiac-electrical-load-schedule-calculator-4817d593"}